Money back guaranteed! A lot of times it could be a bad connection, the harness is bad or the motor itself is bad. New. Press and hold the IN/OUT switch (Fig. THOR #20852. Sold by wsybllc in Chillicothe. Antenna - Satellite. We would then repeat this process a minimum of three times until the system fully retimes. Description. Slide-Out System Fault Code Information (82-L0513) Synchronizing A 2-Rail Slide-Out Room (82-S0304-T) Synchronizing a 2-Rail Slide-Out Room w/ Collared Drive Shaft (82-S0306-T) Control Module for In-Wall Slide-Outs. We Will Take Care Of You! Corporate Code Of Conduct Link opens in a new tab/window California Transparency In Supply Chains Act Disclosures Link opens in a new tab/window. Slide Out Systems provide more living space to RV consumers without compromising overall size. The actuator comes equipped with an automatic clutching system. 9), 27. lippert slide out fault codes. 2021. Qty. Rev: 01.30.2015 Page 10 Lippert In-Wall Troubleshooting Guide Floor Rollers 1. Lippert Components 325979. Lippert Components 13398-D0 This is a newer replacement for the old 13398-C2. Dealer Login Link opens in a new tab/window; Our Story. It is recommended that when operating the Lippert electric slideout system in harsh environments (i.e., road salt, ice buildup, etc.) that the moving parts be kept clean by washing them as needed with mild soap and water. New. Put it in manual mode and try to operate the slide. $256.82 The motor comes equipped with an automatic clutching system. Nothing strikes fear into a camper more than pushing the slide button and nothing happens. 7. You would then depress the in button and bring the slide in 8 to 10 inches. High battery: Voltage greater than 18 volts. Comment. The red and green LED lights will begin to flash indicating you are in override mode 4. It does have a manual mode on this board you will want to try as well. New. Run the slide out the full way and then back in the full way , hold the switch for 5 or so seconds each way. 3. Using a 3/4 socket and ratchet (Fig. Easy-to-clean Polyhyde Vinyl Fabric. Lippert Programmable Slimrack Slide-Out Control Module Park Brake On 404183 Lippert and RVPartsexpress team up to be the leading supplier of components to the recreational vehicle and residential housing industries, as well as adjacent industries including bus, cargo and equestrian trailer, marine, and heavy truck. I've found manuals for the 13398-C2, but not the 13398-D0. Lippert Schwintek Rv Motorhome C2 Synchronous Velocity Slide Controller 13398-d0. The control board will flash an error code to tell you what the issue could be. Battery drop out: Battery capacity low enough to drop below 6 volts while running. Lippert Components Solera Slide Topper Awning Black 96" V000168106. 3. 2015 Chevy 3500HD CC LB Duramax , Reese Elite 18K. Started in 1957, their longevity in the RV industry stands as a testament to the quality workmanship. In the event of any fault code, the unit can be manually overridden electronically using these steps: 1. Not tested. The way to retime the Schwintek system is simple. 1) in the OUT position until the room is fully extended and stops moving. Cause The control box is confused and needs to be reset. Lippert 2020129321 Rv Trailer Left Hand Recliner - Seismic Series Millbrae New Three Stylish Polyhyde Color Options Millbrae, Altoona, And Grummond. Used. Lippert Components are the largest supplier of Slide Out Systems to the US RV Market. + $30.40 shipping. Money back guaranteed! We Are Not An Authorized Dealer Of This Product. Used. Slide-Outs. Manual Override Inside Frame. Refresh your browser window to try again. NOTE: If the slideout switch is held after the room in fully extended, the control will sense that the room has stopped and will shut off the motor after a few seconds. Electric Motor Slide-outOWNERS MANUAL by Lippert Components Contents hide 1 Introduction 2 Safety 3 Operation 4 Maintenance 5 Documents / Resources 5.1 References 5.2 Related Manuals / Resources Introduction The electric slide-out system is designed to provide years of trouble-free operation and reflects the latest state-of-the-art technology. $65.99. When either putting the slide in or out it will move 6 to 8 inches and stop, one side will move about 2 inches further than the other one causing it to bind and stop. More often than not, the problem is a malfunctioning Lippert slide-out motor, which can be caused by poor connection to the onboard battery or an issue with the battery itself. Brian. He recommends swapping motor 1 and motor 2 wiring to see if the single green flash remains or if it goes to two green flashes. The fault code on the controller showed it to be a shorted wire on motor #2. 3 Low battery: Voltage below 8 volts at start of cycle. SLIDE-OUTS Error codes During operation when an error occurs the board will use the LEDs to indicate where the problem exists. Low battery: Voltage below 8 volts at start of cycle. Rev: 03.01.2016 Page 5 Level Up Troubleshooting Guide 5th Wheel Operation Auto Level NOTE: Prior to unhitching from the tow vehicle, ensure unit is parked on a level surface and to chock the tires of the unit. Check for proper roller engagement: A. Rollers should not be digging into the floor of the slide-out. $65.99. $242.52. SKU. Top Rated Plus. Please do not hesitate to reach out. Free shipping. 1510000276 Slide-Out Control Box Reset Procedure. input to the common point of the repay pictured is pictured; but that Release the switch, which will lock the room into position. The Lippert Electric Slideout System is Rev: 02.16.2017 Page 10 Lippert In-Wall Troubleshooting Guide Floor Rollers 1. If it moves to 2 green flashes (motor 2) then the motor or harness is bad and needs to be replaced. 697096. 5. The one green flash you are getting indicates an issue with motor 1. Posted September 5, 2018. Schwintek, Lippert slide out: paulhuyck: RV Systems & Appliances: 8: 08-29-2017 07:17 PM: Schwintek Lippert slide room problems: Bill Thomas: Class A Motorhome Discussions: 3: ONECONTROL IN WALL SLIDE CONTROLLER ASSEMBLY. The item Lippert 13398-D0 RV MOTORHOME Dual Motor Synchronous Velocity Slide Controller is in sale since Tuesday, September 7, 2021. Lippert hydraulic through-frame slide-out service manual Example: dental hygrienist manuals.Heartwners.org hydraulic through the slideout frame troubleshooting proprietary engine manual Before attempting to solve engine problems, make sure that an adequate power source is available. Motor short circuit: Motor or wiring to motor has shorted out. At Lippert, we know how to maximize interior RV space in a way that minimizes weight, simplifies the fitting process and safeguards the unit from outside elements. We manufacture more than 150,000 In-Wall Slide-Out systems for the North America RV and heavy trucking market every year. We also supply slide-outs for caravans in Australia and Europe. Press the mode button six times quickly, press a 7th time and hold for approximately 5 seconds. Long story short I called a mobile RV tech out to take care of the problem. 6. The red LED will flash from two to nine times, depending on the error code. 1. Both controllers are original to my 2007 model year motorhome. Lippert Ground Control 3.0 Electric 5th Wheel RV Leveling System w Touchpad and Remote - 4-Point Set (74 reviews) Rich. I now have had two Lippert brand slide out controllers fail within the last twelve months. The motor drives the ball screw in a forward and backward motion to drive the slide room in and out. The error codes are as follows: 2. You would go to the switch and depress the out button until the slide out fully extends. The slide out control module is flashing red, nine times. Seller 99.1% positive. Symptom One side of the slide-out actuates for a distance before the other side of the slide-out actuates causing the room to actuate at an angle in the coach opening and not perpendicular to the coach opening. Not tested. Slide-Out System Fault Code Information (82-L0513) Synchronizing A 2-Rail Slide-Out Room (82-S0304-T) Synchronizing a 2-Rail Slide-Out Room w/ Collared Drive Shaft (82-S0306-T) These slides are operated from a control panel inside your RV and are very easy to use. Schwintek, Lippert slide out. 2. Prepare to remove the motors and the drive assemblies from one side of the slide-out room, either figure 4-1 and 4-3 or figure 4-2 and 4-4, in order to install the aluminum frame on the room. All Products Recreational Vehicles Cargo Trailers Pontoon Boats Shuttle Buses Commercial Trucks. blink from two to nine times, depending on the error code. Warranty Unspecified Length. Lippert Slide code fault. I was convinced that there was a problem with the wiring like the controller showed. The slides moved freely, but would not go in or out without setting a fault at least three times in each direction. The error codes are as follows: 2 Battery drop out: Battery capacity low enough to drop below 6 volts while running. The override sequence at the controller did not work to retract the slide. Sold by wundercarparts in Kent $862.39 Lippert 134993 RV Carpet Protection Slide-Out Slicker Set. The actuator comes equipped with an automatic clutching system. Lippert 134993 RV Carpet Protection Slide-Out Slicker Set. The motor drives the ball screw in a forward and backward motion to drive the slide room in and out. After unhitching from tow vehicle press Auto Level (Fig. This should get the motors back in sync. At Lippert, we know how to maximize interior RV space in a way that minimizes weight, simplifies the fitting process and safeguards the unit from outside elements. Our Products. I have a brand new Momentum 376TH that has had slide out faults on the One control pad since the day we brought it home. ONECONTROL IN WALL SLIDE CONTROLLER ASSEMBLY. Doesn't seem to coincide with the Fault codes posted on the controller. Brian & Michelle. This Product Has No Manufacturers Warranty. lippert slide out fault codes Home. Continus.us - WiFi Digital Antenna Model CA-1000WIFI Instruction Guide Continus.us - WiFi Digital Antenna Model CA-1000WIFI Instruction Guide copy $64.16. Please do not hesitate to reach out. 1F). The Lippert Electric Slideout System is Locate the hex head crank extension at the top of the actuator inside the chassis main frame (Fig. According to the list on the module, it says Hall Pwr Short to Gnd. + $30.40 shipping. Lippert Components 281331 Slide Out Gear. Mike, the drawing is OK, But very simplified - not a true drawing of how the wiring is installed ! Free shipping Free shipping Free shipping. Starting with the error code is the best place to check. 5. Remove four screws on the end of the drive assembly (Fig. We manufacture more than 150,000 In-Wall Slide-Out systems for the North America RV and heavy trucking market every year. I have a 2014 Solera with a rear bedroom slide problem. Browse Lippert 138416 Hydraulic Hose End Fitting - 1/4'' ID questions and answers, or ask your own Lippert 138416 Hydraulic Hose End Fitting - 1/4'' ID question and receive a knowledgable answer from a topic expert. 3). Posts: 20. February. The controller for the passenger side slide-out failed last October 2017 and the controller for the driver side slide-out failed this past weekend (September 2018). Hello everybody! Check that the seals are not getting caught in the rollers, which could cause binding to the slide-out. The Lippert Electric Slideout System is a rack & pinion guide system, utilizing an electric ball screw actuator to move the room assembly. Seller 99.1% positive. The Lippert Range. 2. 8. I have a slide out code fault on my 2017 Vegas 25.2. NOTE: No park brake input. Manual Operation The Lippert electric slideout system comes with a manual override. Locate the crank extension located outside of the chassis main rail on the opposite side of the slide room. (There will be an access hole in the exterior RV skirt metal to allow insertion of the crank handle). Looks like we're having trouble connecting to our server. 4. Features Led Lighting And Lighted Dual Cupholders. The Lippert Electric Slideout System is a rack & pinion guide system, utilizing an electric ball screw actuator to move the room assembly. 5 Excessive motor current: High amperage, also indicated by one side of slide continually stalling. 2018 Reflection 29RS Oct.2017 build date, EMS-HW50C , Lippert Remote. The error codes are as follows: Locate the circuit board 2. Missing a circuit to supply power to slideroom motor.The drawing pictures one relay to power the in and out voltage to the motor- there are 2 power relays.One to power the slide in and one to power the slide out. Lippert Schwintek Rv Motorhome C2 Synchronous Velocity Slide Controller 13398-d0 . The motor drives the gear that is engaged with the rack under the inner tube to drive the slide room in and out. I noticed it while I was getting my rig ready for the season. that goes into each kit. Thanks to the information on this site, I was able to check for known issues, like the fault codes on the control module and potential 6. $341.95. $440.9545% off. Excessive motor current: High amperage, also indicated by 1 side of slide continually stalling. 4), rotate the extension clockwise to retract the slide-out and counter clockwise to extend the slide-out. For motor specific faults the green LED will flash once for Motor 1, and two times for Motor 2. 4 High battery: Voltage greater than 18 volts. Some kind of ground fault. Browse Lippert 126238 Wet Shoulder Shackle Bolt For Lippert Axles questions and answers, or ask your own Lippert 126238 Wet Shoulder Shackle Bolt For Lippert Axles question and receive a knowledgable answer from a topic expert. The Lippert electric slideout system is a rack and pinion guide system, utilizing a drive gear system to move the room assembly.